Joseph D.

Joseph D. Job Checkin

Heat Pump Estimate West Grove PA Created estimates for installation of new heat pump and boiler replacement.


Joseph D.

Joseph D. Job Checkin

Performed site visit for Peco estimate for home performance as well as heating, Cooling, water heating options. Customer interested in geothermal or heat pump as well as combi propane or geo boiler options.


Joseph D.

Joseph D. Job Checkin

Completed 6 Month inspection for 5 Ton AC/120,000 BTU natural gas furnace. Replaced 16x26x1 filter Tested system in cooling. Temperature split 70-49=21° Good. Measured static pressure. Checked fan speeds. Inspected condition of indoor and outdoor coils. Checked wiring and controls. Left recommendationsfor surge protectors. Inspected drain and components. System has EZ trap and condensate pump safety. Left estimate for wet switch as well which is an additional water safety device. Monitored R410A refrigerant pressures and diagnostics: Good Left estimate for plan membership. Benefits includes reduced diagnostic fees and discounts on repairs and accessories in addition to 2 tune ups per year (1 in heating, 1 in cooling) Discussed and left estimate for APCOX whole home air purification system. Left estimate for smart thermostat. System is operating well at this time.


Joseph D.

Joseph D. Job Checkin

Completed plan member heat tune up for 120,000 BTU natural gas furnace 20x25x1 filter ok Inspected burners, heat exchanger, ignitor, inducer assembly, pressure switches and components Indoor coil is rusty, rust marks on surface of primary heat exchanger Cleaned flame sensor with 0000 steel wool and verified flame rectification circuit Inspected wiring, controls, electric motors and components; left email estimates for surge protection devices. Confirmed proper manifold gas pressures Confirmed inducer vacuum in low and high fire operation Measured temperature rise (68°-118= 50°F) and static pressure Inspected all components of drain. There is no water safety device. Left email estimate for wet switch. Combustion, smoke and draft tests: Pass Discussed and left email estimate for APCOX whole home air purification system. Homeowner paid for Gas Heat+AC plan membership today. Furnace is operating well at the time of this tune up.


Barry P.

Barry P. Job Checkin

2 plan member Heat Tune Ups 1. 50KBTU Natural gas Comfortmaker furnace that serves basement and first floor. Replaced 16x20x1 filter. Made call for heat from thermostat. Measured hot surface ignitor resistance. Cleaned flame sensor; verified flame rectification circuit. Checked pressure switch and components. Measured temperature rise and static pressure. Checked all wiring and motors. Found weak blower capacitor. Homeowner agreed to replace. Inspection of burners ignitor and flame sensor: Good Combustion/draft test: Good Furnace is operating well at the time of this maintenance. 2. 2 Ton Comfortmaker Heat Pump with 8KW strip heater that serves 2nd floor. Replaced both 20x20x1 filters. Checked back up heat/measured amp draw of strip heater. Measured temperature rise. Checked all wiring, electric motors and components. Checked refrigerant pressures. I noted to homeowner a slight buzzing from compressor. Heat Pump system is operating well at the time of this maintenance Both sys


Barry P.

Barry P. Job Checkin

Heat tune up for 120KBTU natural gas furnace: Replaced filter. Made call for heat from thermostat/verified thermostat operation. Visual inspection of burners and heat exchanger. Checked hot surface ignitor ohms and looked for cracks/hot spots during start up. Cleaned flame sensor. Hacked flame sense/rectification circuit. Checked all electric motors and components. Checked temperature rise and static pressure. Checked gas pressure. Combustion draft test: Good Furnace is operating well at the time of this maintenance.


Luis T.

Luis T. Job Checkin

Repiped section of exhaust. Verified that entire length of exhaust was properly pitched.


Barry P.

Barry P. Job Checkin

Gas Furnace Tune Up for 80K BTU 2 stage propane furnace. Checked burners and heat exchanger. Measure temp rise. Measured inlet and outlet gas pressure. Filter ok. Checked all electric motors and components. Checked all field and manufacturer wiring. Combustion test good. Completed Gas Furnace Inspection Form We will schedule to come out and adjust exhaust. Furnace is operating well at the time of six month inspection.


Chris B.

Chris B. Job Checkin

Performed Quality Assurance on Amana Gas Furnace/AC system. Completed checklist form in system. Reviewed installation with homeowner. When we return for Six Month Heating Inspection need to adjust the straps on the Exhaust Pipe to pitch correctly.


Barry P.

Barry P. Job Checkin

Found double pole breaker outdoor breaker tripped. Reset. Found blown terminal on compressor. Will contact Jeff with estimate for compressor replacement.


Barry P.

Barry P. Job Checkin

Found failed condenser fan motor for attic Heat pump. Customer signed estimate to replace motor and fan assembly and become a plan member for both systems in the home. Replace condenser fan motor and blade assembly. 2 GAHP plan memberships.


Barry P.

Barry P. Job Checkin

AC Tune Up for 2.5 Ton Luxaire AC system. 19F temp split. Filter ok. Blew out drain; ok. Tstat operation/cycling of cooling ok. Outdoor voltage/indoor amps/compressor amps ok. All electric motors and components ok. Both coils are in good condition. System is operating well at the time of this tune up. .


Barry P.

Barry P. Job Checkin

AC Tune up for 2.5 Ton ICP AC system.19.5 temp split. Replaced filter. Drain ok. Both coils are in good condition. All electric motors and components ok. Refrigerant pressures/subcooling/superheat ok. Outdoor voltage/indoor amps/compressor amps ok. System is operating well at the time of this maintenance.


Barry P.

Barry P. Job Checkin

AC and Gas Furnace precision tune up. Cleaned tubing of exhaust fitting. Cleaned drain at secondary. Filter. Indoor amps ok. Combustion test good (97% eff.) Temp rise 50F. Filter ok. Explained humidifier operation/settings to Mrs. C. Furnace is operating well at the time of this tune up. Cooling: 15F temperature split. Cleaned evaporator drain/ verified condensate pump operation. Both coils are in good condition. Outdoor voltage/compressor amps/ capacitor ok. Refrigerant pressures/superheat/subcooling ok. System is operating well at the time of this tune up.


Luis T.

Luis T. Job Checkin

Installed t10 smart thermostat with room sensor, and service plan. Heat tune up for 80K BTU single stage Luxaire propane furnace. Cleaned flame sensor. HSI Ohms 45; ok. Adjusted gas pressure from 8.89” WC to 10”WC. Temp rise Heat Pump 16F; temp rise furnace 53. All electric motors and components ok. Combustion test ok. Furnace is working well at the time of this maintenance/tune up.