Performed QA on Laars Boiler install. Spoke with Karen about the system and install. She asked if I could turn the temperature up on the domestic hot water. Adjusted the mixing valve to increase the temperature from 116 Degrees to about 121/122 Degrees. Inspected piping and checked gas piping for leaks. Reviewed programming and Dipswitch settings on the boiler. Completed checklist form in the system. No follow up is needed.
Follow up call for install of heat pump and weatherization work Reviewed scope of work with Daniel, determined it was best to utilize the attic to run ductwork to upper and lower levels. Need to modify quote.
Estimate for new boiler system, West Grove PA Inspected building and equipment. Load calc required. Problems with boiler reliability. Look at oil and propane options.
Heat Pump Estimate West Grove PA Created estimates for installation of new heat pump and boiler replacement.
Performed site visit for Peco estimate for home performance as well as heating, Cooling, water heating options. Customer interested in geothermal or heat pump as well as combi propane or geo boiler options.
Completed 6 Month inspection for 5 Ton AC/120,000 BTU natural gas furnace. Replaced 16x26x1 filter Tested system in cooling. Temperature split 70-49=21° Good. Measured static pressure. Checked fan speeds. Inspected condition of indoor and outdoor coils. Checked wiring and controls. Left recommendationsfor surge protectors. Inspected drain and components. System has EZ trap and condensate pump safety. Left estimate for wet switch as well which is an additional water safety device. Monitored R410A refrigerant pressures and diagnostics: Good Left estimate for plan membership. Benefits includes reduced diagnostic fees and discounts on repairs and accessories in addition to 2 tune ups per year (1 in heating, 1 in cooling) Discussed and left estimate for APCOX whole home air purification system. Left estimate for smart thermostat. System is operating well at this time.
Completed plan member heat tune up for 120,000 BTU natural gas furnace 20x25x1 filter ok Inspected burners, heat exchanger, ignitor, inducer assembly, pressure switches and components Indoor coil is rusty, rust marks on surface of primary heat exchanger Cleaned flame sensor with 0000 steel wool and verified flame rectification circuit Inspected wiring, controls, electric motors and components; left email estimates for surge protection devices. Confirmed proper manifold gas pressures Confirmed inducer vacuum in low and high fire operation Measured temperature rise (68°-118= 50°F) and static pressure Inspected all components of drain. There is no water safety device. Left email estimate for wet switch. Combustion, smoke and draft tests: Pass Discussed and left email estimate for APCOX whole home air purification system. Homeowner paid for Gas Heat+AC plan membership today. Furnace is operating well at the time of this tune up.
2 plan member Heat Tune Ups 1. 50KBTU Natural gas Comfortmaker furnace that serves basement and first floor. Replaced 16x20x1 filter. Made call for heat from thermostat. Measured hot surface ignitor resistance. Cleaned flame sensor; verified flame rectification circuit. Checked pressure switch and components. Measured temperature rise and static pressure. Checked all wiring and motors. Found weak blower capacitor. Homeowner agreed to replace. Inspection of burners ignitor and flame sensor: Good Combustion/draft test: Good Furnace is operating well at the time of this maintenance. 2. 2 Ton Comfortmaker Heat Pump with 8KW strip heater that serves 2nd floor. Replaced both 20x20x1 filters. Checked back up heat/measured amp draw of strip heater. Measured temperature rise. Checked all wiring, electric motors and components. Checked refrigerant pressures. I noted to homeowner a slight buzzing from compressor. Heat Pump system is operating well at the time of this maintenance Both sys
Heat tune up for 120KBTU natural gas furnace: Replaced filter. Made call for heat from thermostat/verified thermostat operation. Visual inspection of burners and heat exchanger. Checked hot surface ignitor ohms and looked for cracks/hot spots during start up. Cleaned flame sensor. Hacked flame sense/rectification circuit. Checked all electric motors and components. Checked temperature rise and static pressure. Checked gas pressure. Combustion draft test: Good Furnace is operating well at the time of this maintenance.
Repiped section of exhaust. Verified that entire length of exhaust was properly pitched.
Gas Furnace Tune Up for 80K BTU 2 stage propane furnace. Checked burners and heat exchanger. Measure temp rise. Measured inlet and outlet gas pressure. Filter ok. Checked all electric motors and components. Checked all field and manufacturer wiring. Combustion test good. Completed Gas Furnace Inspection Form We will schedule to come out and adjust exhaust. Furnace is operating well at the time of six month inspection.